ST3022 Digital Temperature humidity Controller – essential tool for electronics prototyping and college labs. ₹1434 | Same-day dispatch | Pan-India delivery from Syntronix, Bangalore.

SKU: SYN-PRO-0087 Category: Tag:
Description

Description

Digital Temperature and humidity Controller thermostat with Sensor for industrial use.

  • Control range: 1%RH-99%RH
  • Load power: 10A/AC220V
  • Measurement range: -20°~80°
  • Humidity range: 1%RH-99%RH
  • Measurement error: ±3%RH(environment temperature at 25°)
  • Temperature precision: 1° Humidity precision:1%RH
  • Display accuracy: 1%RH
  • Power Supply: DC12V/24V/220V(Choose)
  • Output type: 10A relay output probe type
  • Temperature: NTC precision ±1°
  • Humidity: Resistance type sensor precision ±3°
  • Dimension: 90*60*26.5mm(L*W*H)
  • Temperature control object: one channel temperature(heating and refrigeration ventilator Or humidity(Dehumidify or humidify electrical appliance)
  • Probe line length: standard 1.5m
  • Permanent memory of parameter: set the all parameter with permanent memory
  • Power failure at the operation time: run after the power supply.
  • Working environment: temperature 0-55° humidity90%RH without condensation

Note: Item color displayed in photos may be showing slightly different on your computer monitor since monitors are not calibrated same.

Humidity control setting: Press Set keyboard one time, press three second enter into setting menu after humidity display flashing, it will display code HC. Press “▲ “keyboard or “▼”keyboard can cyclical selection HC-CP-PU-CA-HP parameter code. Please press Set keyboard if you need enter into a code, press “▲ “keyboard or “▼”keyboard to modify the required numerical for five seconds then return automatically.

Press “SET” keyboard twice enter into setting menu after temperature display flashing, and display code HC, press “▲ “keyboard or “▼”keyboard can cyclical selection HC-CP-PU-CA-HP parameter code, please press “SET “ keyboard if you need enter into one code, press “▲ “keyboard or “▼”keyboard to modify the required numerical for five seconds then return automatically.

Dehumidification control: The way of mode control (code HC) it will be dehumidification control when setting as C. For example, set the humidity control value as 50% RH and humidity difference as 5%, relay start output, When environment humidity value ≤setting humidity value(50%RH), relay close output.

Damping control: The way of humidity control (code HC), set H as damping mode, for example, set the humidity control value as 50%RH and humidity difference as 5%RH. When temperature humidity value ≤setting value(50%RH)-difference/(5%RH), relay start output. when temperature humidity ≥ setting value(50%RH), relay stop output.

HC: mode selection, H means humidifying mode, C means dehumidification mode.

D: return difference, start the humidify when in the humidifying mode=displaying humidity-return difference. start the humidify when in dehumidification mode=displaying humidity + return difference.

PU: Delay to start. when relay stop output and start timing. the interval time of next boot must greater than delay start time to avoid start frequently.

HP: Humidity upper limit alarm: when humidity exceed upper limit alarm, digital tube displaying “-H-”,humidity lower than alarm setting value it will return back from alarm automatically.

LS; Humidity lower limit alarm: When humidity exceed lower limit, digital tube display”-L-”,humidity higher than alarm setting value it will return back from alarm automatically.

CA: Humidity correction: Humidity correction value plus displaying value. For example: humidity display 50% RH correction humidity increase 5% RH, then display humidity will be 55%RH.

Heating mode: Mode control way (code HC) set as H, it is heating mode. For example, set control heating value as 35°,temperature return difference is 2°. when environment humidity value ≥ setting temperature value(35°)-return difference(2 °), relay start output. when humidity value ≤ setting humidity value (35°), relay close output.

Cooling control: The way of mode control ,set (HC code) as C ,it is cooling mode. For example, set cooling as 35 ° and temperature return difference as 2 °.When environment value ≥ setting temperature value (35°)+return difference(2°), relay start output: when environment humidity value ≤ setting humidity value(35 °),relay stop output.

HC: Mode selection, C means cooling mode, H means heating mode.

D:return difference, start temperature when in heating mode= displaying temperature”-return difference. Start temperature when in cooling mode=displaying temperature + return difference.

PU: Delay to start, When relay stop output and start timing, the interval of time must greater than delay start time to avoid start frequently. HP: temperature upper limit alarm: when temperature exceed upper limit alarm, digital tube display ”HHH” ,temperature lower than alarm setting it will return back from alarm automatically.

LS: temperature lower limit alarm: when temperature exceed than lower limit alarm, digital tube display “LLL”, temperature higher than alarm setting it will return back from alarm automatically.

CA temperature correction: Humidity correction value plus display humidity value, for example: humidity displaying 35° ,correction humidity increase 5°,then temperature should be 35°.

Reset: Press left up and down keyboard until screen displaying 888,then it will coma back to factory reset.

Additional information

Additional information

Weight

0.05 kg

Dimensions

10 × 10 × 10 cm

HSN Code

85177010

Mfr. part no.

NA

Package

NA

Part No

NA

Datasheet

NA

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ST3022 Digital Temperature humidity Controller”

Your email address will not be published. Required fields are marked *

Shipping & Delivery
hipping Overview Dispatch Time Within 1–2 business days from Bangalore Cutoff Time Orders placed before 3 PM IST are shipped same/next business day Courier Partners Delhivery, BlueDart, DTDC, India Speed Post Coverage Pan-India only. No international shipping. Tracking Tracking details sent to your registered email after dispatch Delivery Time Metro Cities 1–3 business days Other Locations 3–7 business days Delivery timelines are estimates and depend on the courier partner. Syntronix is not responsible for delays caused by third-party carriers. Shipping Charges Free Shipping On all orders above ₹499 Below ₹499 Nominal shipping fee calculated at checkout based on location Cash on Delivery (COD) Available on orders ₹500–₹3,000. A processing fee of ₹125 applies. All orders are shipped with a GST invoice as per Indian tax regulations. Please enter your GST details at checkout if required — GST details cannot be updated after order placement. Returns & Refunds Return Window 7 days from date of delivery Eligible Returns Defective or damaged products only Process Email info@syntronix.in with your order ID and photos of the product Refund Timeline 3–5 working days after return inspection and approval Products must be returned in original packaging with all accessories. Return shipping costs are borne by the customer unless the product is defective. Returns are not accepted for products damaged due to misuse, accident, or improper handling. Cancellations Cancellations can be requested before the order is shipped by emailing info@syntronix.in or via WhatsApp. Once an order has been shipped, cancellations cannot be processed. Damaged Parcels If your parcel appears damaged or tampered with at the time of delivery, please refuse to accept it and contact us immediately at info@syntronix.in with your order reference number. We will arrange a replacement at the earliest. Bulk & B2B Orders For institutional purchases, college lab orders, or bulk B2B enquiries, contact us directly at info@syntronix.in or via the WhatsApp button on the website.